If you want to enjoy swimming in any time with energy efficient, the best way to do this is to operate the swimming pool heat pump
FeaturesA pool heat pump uses a small amount of electricity to carry on.Instead of heating with an electric heating element they collect heat from the outside air.Even when it is 50 degrees outside there is enough heat in the air to put in the pool even though it feels cold to us.In other words, you are just really moving existing heat around from the air to your water.This heat is removed from the air, concentrated with your compressor, and then transferred to the water. More powerful-meidibao commercial pool heat pumps have a wide range of capacity from 10 to 210kw, which can be used for very large swimming pool like stadium, hotel and school.Mdb models are the perfect solution for larger above ground and in-ground pools. |
More comfortable- the normal pool heat pumps only produce heating energy but in times of summer, the ambient is very hot and the pool water is also hot too, this is not ideal condition for swimming, the too warm water may ma-ke people easy to get tired and it is also not good for your health, meidibao's pool heat pumps included a reversi-ng valve which can convert the status between condenser and evaporator that can cool or heat the pool water to be favourable condition with automatically changing according to the actual environment. More safe- pool heat pump utilize reverse carnot principle, the cold refrigerant via evaporator absorb heat energy from air then compressed by compressor to be high temperature gas via condenser release the heat to water, it's not like the normal electric heater to touch water directly.So the heat pump pool heater is more safer.Besides this meidibao's pool heat pumps have several protection mode which can further ensure users security. |
Energy-efficient operation of a heating system depends above all on an effective control system that the heat pu-mp is fitted with.Intelligent electronic control units in meidibao heat pumps monitor the operation of the equipment according to the external input-output parameters, steering the circulation pumps, mixing valves, immersion pum-ps, shut-off valves, etc.The controller also has comprehensive protection and early warning function, it always m-onitor the system while it is operating or in standby condition.If the unit cannot be started or shut down in operati-on, the fault code will be displayed. Titanium heat exchangers utilize rifled titanium, in a coaxial, or "tube in tube" configuration.Rifled titanium tubing i-nside the heat exchanger swirls the water and refrigerant efficiently.The expanded surface area of the rifled tit-anium maximizes its contact with the refrigerant and water, providing heat transfer at a greater rate.And since it's titanium, it will never corrode or wear out.The results are more heat for less money, making a pool heater with a -titanium heat exchanger the most efficient pool heat pump in the world. |
Model | M-C10AAS | M-C11AAS | M-C19AAS | M-C24AAS | M-C35AAS | M-C42AAS | M-C52AAS | ||
Performance at A:15/12ºC W:26/29ºC | Heating capacity | kW | 9.8 | 10.5 | 19 | 24.5 | 35.2 | 42 | 52.5 |
Input power | kW | 2.45 | 2.63 | 4.75 | 6.1 | 8.72 | 10.5 | 13.1 | |
C O P | w/w | 4 | 4 | 4 | 4 | 4.03 | 4 | 4 | |
Current | A | 11.1 | 4.6 | 8.4 | 10.8 | 15.5 | 18.6 | 23.1 | |
Performance at A24/19ºC W26/29ºC | Heating capacity | kW | 12 | 13 | 21.8 | 30.5 | 43.5 | 52.3 | 65.3 |
Input power | kW | 2.24 | 2.42 | 4.08 | 5.71 | 8.14 | 9.78 | 12.2 | |
C O P | w/w | 5.34 | 5.34 | 5.34 | 5.34 | 5.34 | 5.34 | 5.34 | |
Current | A | 10.2 | 4.3 | 7.2 | 10.1 | 14.4 | 17.3 | 21.5 | |
Max input power | kW | 3.96 | 3.96 | 7.1 | 7.9 | 13.6 | 15.8 | 20.4 | |
Max current | A | 18 | 7 | 12.5 | 14 | 24 | 28 | 36 | |
Power supply | / | 220V~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | |
Rated water flow volume | (m³/h) | 3.4 | 3.7 | 6.24 | 8.74 | 12.7 | 15 | 18.7 | |
Refrigerant type/volume | (g) | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | |
Applied swimming pool volume | m³ | 9 | 9 | 15 | 21 | 30 | 36 | 45 | |
Type of heat exchanger | / | PVC-titanium | |||||||
Rated water supply temperature | ºC | 45 | 45 | 45 | 45 | 45 | 45 | 45 | |
Max water supply temperature | ºC | 45 | 45 | 45 | 45 | 45 | 45 | 45 | |
Size of connection port | inch | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Compressor QTY | 1 | 1 | 1 | 1 | 2 | 2 | 3 | ||
Screw materials | / | Stainless | |||||||
Working condition range | (ºC) | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | |
Fan QTY | 1 | 1 | 1 | 1 | 2 | 2 | 2 | ||
Noise level | dB(A) | 64 | 64 | 68 | 74 | 71 | 76 | 76 | |
Net dimensions | mm | 750×690 ×880 |
750×690 ×880 |
750×690 ×1060 |
750×690 ×1500 |
1360×690 ×1360 |
1360×690 ×1600 |
1600×1000 ×1920 |
|
Fan direction | / | Top | |||||||
Net weight | kg | 110 | 110 | 160 | 175 | 310 | 380 | 432 |
Model | M-C70AAS | M-C87AAS | M-C105AAS | M-C122AAS | M-C140AAS | M-C168AAS | M-C210AAS | ||
Performance at A:15/12ºC W:26/29ºC | Heating capacity | kW | 70 | 87.5 | 105 | 122.5 | 140 | 168 | 210 |
Input power | kW | 17.5 | 21.9 | 26.3 | 30.6 | 35 | 42 | 52.5 | |
C O P | w/w | 4 | 4 | 4 | 4 | 4 | 4 | 4 | |
Current | A | 30.9 | 38.7 | 46.5 | 54 | 61.8 | 74 | 92.8 | |
Performance at A24/19ºC W26/29ºC | Heating capacity | kW | 87 | 108.7 | 130 | 152.3 | 174 | 217.5 | 261 |
Input power | kW | 16.3 | 20.3 | 24.3 | 35.1 | 32.6 | 40.7 | 48.9 | |
C O P | w/w | 5.33 | 5.35 | 5.34 | 5.33 | 5.33 | 5.34 | 5.33 | |
Current | A | 28.8 | 35.9 | 43 | 62 | 57.6 | 72 | 86 | |
Max input power | kW | 27.2 | 31.7 | 40.7 | 47.5 | 54.3 | 58.9 | 81.5 | |
Max current | A | 48 | 56 | 72 | 84 | 96 | 104 | 144 | |
Power supply | / | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | 380V 3N~/50Hz | |
Rated water flow volume | (m³/h) | 25 | 31 | 37.2 | 43.6 | 50 | 62.3 | 75 | |
Refrigerant type/volume | (g) | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | R410A/ | |
Applied swimming pool volume | m³ | 60 | 75 | 90 | 105 | 120 | 150 | 180 | |
Type of heat exchanger | / | PVC-titanium | |||||||
Rated water supply temperature | ºC | 45 | 45 | 45 | 45 | 45 | 45 | 45 | |
Max water supply temperature | ºC | 45 | 45 | 45 | 45 | 45 | 45 | 45 | |
Size of connection port | inch | 3 | 3 flange | 3flange | 4flange | 4flange | 4flange | 4flange | |
Compressor QTY | 4 | 4 | 6 | 6 | 4 | 4 | 6 | ||
Screw materials | / | Stainless | |||||||
Working condition range | (ºC) | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | 0-43 | |
Fan QTY | 2 | 2 | 2 | 2 | 4 | 4 | 6 | ||
Noise level | dB(A) | 78 | 78 | 78 | 78 | 78 | 78 | 78 | |
Net dimensions | mm | 1800×1000 ×2020 |
2200×1000 ×2020 |
2200×1000 ×2020 |
2400×1000 ×2020 |
2000×1800 ×2020 |
2000×2000 ×2020 |
3000×1800 ×2020 |
|
Fan direction | / | Top | |||||||
Net weight | kg | 660 | 730 | 890 | 1076 | 1350 | 1420 | 1620 |